Isaro Pro / IP 12L70 740 ENR M BP 3550 ZU CL2 ->

92930849

Data Sheet

A state of the art LED road lighting lantern (small) with 12 LEDs driven at 700mA with Extra Narrow Road optic. Programmable LED driver. Class II electrical, IP66, IK09. Housing: die-cast aluminium (EN AC-44300), powder coated textured anthracite (close to RAL7043). Spigot: die-cast aluminium (EN AC-44300), powder coated textured anthracite (close to RAL7043). Enclosure: 5mm thick glass. Fixings: stainless steel. Supplied with Ø60mm spigot adaptor pre-fitted for post-top, 5° tilt. Equipped with 50% power reduction circuit, effective 3 hours before and 5 hours after a calculated midnight. Equipped with 1 Zhaga socket. Pre-wired with 8m cable. Complete with 4000K LED. Surge protection: 10kV single pulse common mode and 8kV multipulse common mode and 6kV multipulse differential mode. If permanent DALI system is connected, 6kV multipulse common and differential mode.

Dimensions: 571 x 224 x 114 mm
Luminaire input power: 26.2 W
Luminaire luminous flux: 3938 lm
Luminaire efficacy: 150 lm/W
Weight: 5.6 kg
Scx: 0.054 m²

Mode selection
  • Lamp position:STD - standard
  • Light Source:LED
  • Luminaire luminous flux*:3938 lm
  • Luminaire efficacy*:150 lm/W
  • Colour Rendering Index min.:70
  • Ballast:1 x 96277236 DRV OS OTDX 40W 1.05A 56V D #C OD
  • Correlated colour temperature*:4000 Kelvin
  • Chromaticity tolerance (initial MacAdam):5
  • Rated useful life (B10)*:L95 100000 h at 25 °C
  • Luminaire input power*:26.2 W Power factor = 0.89
  • Dimming:PROG
  • LED
  • CE
  • GLedReP
  • IK09
  • IP66
  • Coastal_C5
  • LLedNr
  • SC2 - Protection Class 2
  • UKCA

Photometry

Photometric configuration

CalcExpress

Use CalcExpress to quickly carry out quick online calculations of required indoor luminaire numbers for rectangular rooms. Enter the calculation parameters for your solution such as room dimensions, mounting height, height of the useful plane and required level of illuminance, and the site will instantly suggest a solution according to the light output ratio method.

Step 1: Technical data
(lm)
(m)
(m)
(%)
Step 2: Room Data
(m)
(m)
(m)
(m)
(%)
Step 3: Result
(lx)
(%)