Voyager Fit / VOYAGER FIT MRC E3T NM

96629567

Change configuration

  • Base: 96629567 — VOYAGER FIT MRC E3T NM
  • Optic: ANT: open area emergency optic

Data Sheet

Self contained, ceiling recessed, emergency lighting luminaire with 3 hour, SelfTest, emergency lighting circuit, non-maintained. Housing: white (close to RAL9016) polycarbonate. Battery strap: red rubber incorporating cable. Suitable for mounting into ceiling thicknesses from 1 to 25mm. Class II electrical, IP20, IK03. Ceiling cut-out Ø40mm, void 80mm minimum. Pre-wired with 250mm, low smoke, halogen free 0.75mm² stranded cable with prepared ends. Complete with 6500K LED.

Interchangeable optics for anti-panic, escape route and spot applications included.


Dimensions: Ø51 x 94 mm
Weight: 0.23 kg

Self-contained emergency luminaires rely on long-lasting batteries. Voyager Fit's high-tech lithium iron phosphate battery is robust and comes with a three-year guarantee (applicable subject to the terms and conditions of and to the extent as set forth in the manufacturer's guarantee on Thorn products, which shall be applicable analogously and which is available under http://www.thornlighting.com/en/products/5-year-guarantee/5-year-warranty/terms-of-guarantee_en.pdf. The battery guarantee shall not come into effect if the product has been installed later than three(3) months after delivery EXW (Incoterms 2010).

Equipped with:

  • Optics transparent polycarbonate lens for anti-panic emergency lighting. Set of three lenses supplied with the luminaire.
Mode selection
  • Lamp position:ANT (open area optic)
  • Light Source:LED
  • Luminaire luminous flux*:200 lm
  • Colour Rendering Index min.:80
  • Ballast:1 x 89800540 Voyager FIT MRC E3T NM
  • Correlated colour temperature*:6500 Kelvin
  • Chromaticity tolerance (initial MacAdam):3
  • Rated median useful life*:L90 50000 h at 30 °C
  • Standby Power*:0.6 W
  • Charging power:2.5 W
  • LED
  • BSI
  • CE
  • ENEC
  • 850°
  • IK03
  • IP20
  • SC2 - Protection Class 2
  • Ta = +5 to +30
  • UKCA

Photometry

Photometric configuration

CalcExpress

Use CalcExpress to quickly carry out quick online calculations of required indoor luminaire numbers for rectangular rooms. Enter the calculation parameters for your solution such as room dimensions, mounting height, height of the useful plane and required level of illuminance, and the site will instantly suggest a solution according to the light output ratio method.

Step 1: Technical data
(lm)
(m)
(m)
(%)
Step 2: Room Data
(m)
(m)
(m)
(m)
(%)
Step 3: Result
(lx)
(%)